Power System Analysis
- Power system analysis 1
- Power system analysis, supplementary model
- Power system analysis, basic model
- Power systems analysis, advanced model
- Comprehensive power system analysis
- Energy systems analysis
- Relay and protection, basic model
- Relay and protection, supplementary model
- Relay and protection, advanced model
- Relay and protection, substation protection model
- Relay and protection and power system
- Relay and protection of substation and power system
- Substation relay and protection, overcurrent model
- Substation relay and protection, differential model
- Substation relay and protection, distance model
- Relay & Protection
-
Renewable Energy
- Induction Machines
- Transformers
- Electrical Machines 1
- Synchronous Machines
- Induction Machines Drive
- Advanced Model
- AC Machines
- Special Machines
- Software Based Monitoring and Control
- 3-Phase Multifunction Machine
- Multi-function DC machine
- Shunt DC machine
- Series DC Machine
- Compound DC Machine
- Universal Machine
- Permanent Magnet DC Machine
- Permanent Magnet Synchronous Machine
- electronic power
-
control systems
- Analog Linear Control
- Modular Digital Control
- Analogue and Digital Servo Motor Control
- Industrial Control Training Set, Temperature Control
- Industrial Control Training Set, Pressure Control
- Industrial Control Training Set, Level and Flow Control
- Industrial Control Training Set, Motor Speed Control
- Advanced Router Robot
-
precision automation tools
- LOGO PLC, Basic Model
- PLC LG, The Base Model
- S7-300 PLC, Advanced Model
- Industrial Network With S7-300 PLC
- Computer-based Control
- Industrial Monitoring, Basic Model
- Instrumentation, Basic Model
- Instrumentation, Supplementary Model
- Industrial Drives
- Electro-pneumatic, Basic Model
- Electro-pneumatic, Advanced Model
- Electro-pneumatic, Supplementary Model
-
electronic
- Integrated Circuits, Analog Electronic Training Set
- Pulse Technique Circuits, Analog Electronic Training Set
- Electronic 1 Circuits, Analog Electronic Training Set
- Electronic 2 Circuits, Analog Electronic Training Set
- Electronic 3 Circuits, Analog Electronic Training Set
- Electronic Circuits, Analog Electronic Training Set
- Logic Circuits
- Digital Systems 1
- AVR Micro-Controller
- ARM Micro-Controller
- PIC Micro-Controller
- Digital Systems 2
- Digital Signal Proccessing
- telecommunications
- construction facilities and smart building
- industrial facilities
Advanced Model - MC-105

This system is specially designed and produced for training theoretical and practical concepts of induction, synchronous, DC machines and transformer.
Features:
• Isolated measuring and monitoring of three-phase voltages and currents through a DAQ card
• Software-based speed, power, torque, voltage and current monitoring
• Applying variable mechanical load on electrical machines based on magnetic brake
• Possibility to apply linear and nonlinear electrical loads on transformers and electrical machines
• Inverter-based speed control
• Three-phase voltage control using autotransformer
• Simultaneous voltage, current, power, power factor and frequency measuring
• Simultaneous DC voltage and current measuring
• Ability to synchronize synchronous machine with AC network
Features:
• Isolated measuring and monitoring of three-phase voltages and currents through a DAQ card
• Software-based speed, power, torque, voltage and current monitoring
• Applying variable mechanical load on electrical machines based on magnetic brake
• Possibility to apply linear and nonlinear electrical loads on transformers and electrical machines
• Inverter-based speed control
• Three-phase voltage control using autotransformer
• Simultaneous voltage, current, power, power factor and frequency measuring
• Simultaneous DC voltage and current measuring
• Ability to synchronize synchronous machine with AC network
1) DAQ card to receive measuring signals of three-phase voltages and currents and magnetic speed sensor
2)The software for monitoring electrical and mechanical signals of electrical machines
3) Three-phase voltage and current isolators
4) 350W, 380V, 3-phase and 2-pole AC multi-function machine
5) 350W, 220V, 2-pole, multi-function DC machine
6) Up to 5kRPM, Magnetic tachometer
7) 0-120% output, three-phase autotransformer
8) Residual-current fuse and stop-start circuit
9) Stepwise resistor, inductor and capacitor
10) three-phase multifunction meter
11) Digital multimeter
12) Mechanical coupling of DC, synchronous and induction machines with another induction machine
13) Two 0-35V, 1A, DC sources
14) 0-220V, 0-100Hz three-phase inverter
15) 950W, 190V/190V/380V, three-phase transformer
16) 150W, 190V/380V, single-phase transformer
17) Three-phase ammeter and voltmeter
18) Single-phase and three-phase diode bridge
19) Synchronizer by use of filament lamps
20) DC voltmeter and ammeter
21) 0-120% variable output, DC power supply
2)The software for monitoring electrical and mechanical signals of electrical machines
3) Three-phase voltage and current isolators
4) 350W, 380V, 3-phase and 2-pole AC multi-function machine
5) 350W, 220V, 2-pole, multi-function DC machine
6) Up to 5kRPM, Magnetic tachometer
7) 0-120% output, three-phase autotransformer
8) Residual-current fuse and stop-start circuit
9) Stepwise resistor, inductor and capacitor
10) three-phase multifunction meter
11) Digital multimeter
12) Mechanical coupling of DC, synchronous and induction machines with another induction machine
13) Two 0-35V, 1A, DC sources
14) 0-220V, 0-100Hz three-phase inverter
15) 950W, 190V/190V/380V, three-phase transformer
16) 150W, 190V/380V, single-phase transformer
17) Three-phase ammeter and voltmeter
18) Single-phase and three-phase diode bridge
19) Synchronizer by use of filament lamps
20) DC voltmeter and ammeter
21) 0-120% variable output, DC power supply