Power System Analysis
- Power system analysis 1
- Power system analysis, supplementary model
- Power system analysis, basic model
- Power systems analysis, advanced model
- Comprehensive power system analysis
- Energy systems analysis
- Relay and protection, basic model
- Relay and protection, supplementary model
- Relay and protection, advanced model
- Relay and protection, substation protection model
- Relay and protection and power system
- Relay and protection of substation and power system
- Substation relay and protection, overcurrent model
- Substation relay and protection, differential model
- Substation relay and protection, distance model
- Relay & Protection
-
Renewable Energy
- Induction Machines
- Transformers
- Electrical Machines 1
- Synchronous Machines
- Induction Machines Drive
- Advanced Model
- AC Machines
- Special Machines
- Software Based Monitoring and Control
- Power Electronics Trainer
- 3-Phase Multifunction Machine
- Multi-function DC machine
- Shunt DC machine
- Series DC Machine
- Compound DC Machine
- Universal Machine
- Permanent Magnet DC Machine
- Permanent Magnet Synchronous Machine
- electronic power
-
control systems
- Analog Linear Control
- Modular Digital Control
- Analogue and Digital Servo Motor Control
- Industrial Control Training Set, Temperature Control
- Industrial Control Training Set, Pressure Control
- Industrial Control Training Set, Level and Flow Control
- Industrial Control Training Set, Motor Speed Control
- Advanced Router Robot
-
precision automation tools
- LOGO PLC, Basic Model
- PLC LG, The Base Model
- S7-300 PLC, Advanced Model
- Industrial Network With S7-300 PLC
- Computer-based Control
- Industrial Monitoring, Basic Model
- Instrumentation, Basic Model
- Instrumentation, Supplementary Model
- Industrial Drives
- Electro-pneumatic, Basic Model
- Electro-pneumatic, Advanced Model
- Electro-pneumatic, Supplementary Model
-
electronic
- Integrated Circuits, Analog Electronic Training Set
- Pulse Technique Circuits, Analog Electronic Training Set
- Electronic 1 Circuits, Analog Electronic Training Set
- Electronic 2 Circuits, Analog Electronic Training Set
- Electronic 3 Circuits, Analog Electronic Training Set
- Electronic Circuits, Analog Electronic Training Set
- Logic Circuits
- Digital Systems 1
- AVR Micro-Controller
- ARM Micro-Controller
- PIC Micro-Controller
- Digital Systems 2
- Digital Signal Proccessing
- telecommunications
- construction facilities and smart building
- industrial facilities
Relay and protection and power system - Model RP-104
Relay and protection, basic model Training set is designed based on new topics approved by the Ministry of Science and has a written agenda. This device is used to provide relay and protection laboratories as well as training personnel of power distribution companies, industries and factories. The capabilities of this device include the following:
• Possibility to simultaneous study of power system and protection
• The ability to observe and record three-phase current and voltage transient waveforms
• The ability to observe fault signals and relay reactions simultaneously
• Digital voltage protection relay studies including over and under voltages
• Digital overcurrent protection relay consideration
• The ability to protect transmission lines, buses and transformers
• Two medium transmission lines with series and shunt connections capability
• Power transmission substations with controllable circuit Breakers and isolators
• Analysis of nonlinear loads effects on relay operation
• Simulation capability for different fault types
• Possibility to simultaneous study of power system and protection
• The ability to observe and record three-phase current and voltage transient waveforms
• The ability to observe fault signals and relay reactions simultaneously
• Digital voltage protection relay studies including over and under voltages
• Digital overcurrent protection relay consideration
• The ability to protect transmission lines, buses and transformers
• Two medium transmission lines with series and shunt connections capability
• Power transmission substations with controllable circuit Breakers and isolators
• Analysis of nonlinear loads effects on relay operation
• Simulation capability for different fault types
1) Infinite bus model
2) Series and parallel capacitor
3) Equipment with different protection fuses
4) Substation model
5) Shunt reactor
6) Transmission lines
7) Three-phase transformer
8) Three-phase multifunction meters
9) Linear electrical loads included resistors, inductor and electrical motor
10) Measureing power angle
11) Nonlinear electrical load
12) Digital timer
13) Current protection relay
14) Voltage protection relay
2) Series and parallel capacitor
3) Equipment with different protection fuses
4) Substation model
5) Shunt reactor
6) Transmission lines
7) Three-phase transformer
8) Three-phase multifunction meters
9) Linear electrical loads included resistors, inductor and electrical motor
10) Measureing power angle
11) Nonlinear electrical load
12) Digital timer
13) Current protection relay
14) Voltage protection relay